Diesel generator sets are the main backup power produced by manufacturing companies. The main fuel used is diesel. At present, as the price of oil continues to rise, engine oil is also rising. In order to reduce the cost of use, the most important thing is to use the generator set. Reduce the oil consumption of the engine oil as much as possible, and do well to save fuel. Then as a user of the generator set. How to use the fuel quantity of diesel generator set?
First, we need to understand the reasons for excessive oil consumption before we can take corresponding measures.
First, normal wear caused by long-term use of the engine, or abnormal wear caused by improper maintenance, will cause the cylinder liner of the diesel engine to form longitudinal pull marks, and the cylinder bore and piston side clearance will exceed the specified values, which will reduce the support of the piston ring accordingly. Small, the phenomenon of oil scraping is not clean. Or the internal support twist spring in the oil ring is disconnected at the opening position of the oil ring, causing the oil scraping to be dirty and participating in combustion, causing severe oil consumption symptoms, manifested as difficulty in starting the diesel engine, and obvious blue smoke from the exhaust pipe. , The respirator is seriously fuelling. In addition, the side of the piston that should have been turned upside down caused the combustion chamber to be turned upside down during assembly. Although the starting of the diesel engine will not be affected, the loss of oil will be quite serious, and the fuel consumption will be about 0.5 kg per day.
2. When excessive oil consumption is found, first check whether there is any oil leakage at the connection between the body and the gear room cover, the large disk on the side of the wheel, the rear cover, and the cover. Attention should be paid to the integrity of the gaskets at each connection. Replace damaged gaskets. If the gasket is intact, check whether the connecting screws in all parts are loose. Use a wrench to tighten the loose bolts to the specified torque. If the above parts are basically normal, and the oil leakage is in the rack position, the oil casing should be inspected. The main inspection part is at the front end of the oil casing side on the same side as the row wheel. There is a long-term friction between the lower frame and the angle iron protecting the oil casing, and the oil casing is ground through to form a gap, resulting in oil leakage.
3. Severe abrasion of the valve guide will also affect the oil consumption of the diesel generator set.
How can we better make the machine more fuel efficient?
1. Maintain the optimal fuel supply angle: deviation of the fuel supply angle will cause the fuel supply time to be too late and the fuel consumption will increase greatly.
2. Ensure that the machine does not leak oil: the treatment method is to apply the valve paint on the gasket and smooth it on the glass plate to straighten the oil pipe joint. An additional diesel recovery device can be added. A plastic pipe can be used to connect the oil return pipe on the oil nipple with an air-core screw to allow the return oil to flow into the fuel tank.
3. Increase the temperature of diesel engine cooling water: Increasing the water temperature can make diesel more complete combustion, the viscosity of the engine oil will be small, it can reduce the movement resistance, and it can achieve the fuel saving effect.
4. Properly increase the diesel engine pulley, increase the speed of the pump under the condition that the diesel engine runs at a reduced speed, increase the flow rate and head, and achieve the purpose of energy saving.
5. Purify the fuel before use: more than half of the failures of diesel generators come from the oil supply system. The treatment method is that the purchased diesel can be left to settle for 2-4 days and then used, which can precipitate 98% of impurities. If you buy it now, you can put two layers of silk cloth or toilet paper at the fuel filler screen.
6. Adjust the injection pressure of the injector.
I believe that as long as the above six energy-saving schemes are done, the fuel consumption of diesel generator sets will be greatly reduced, and the working efficiency of the generator set will be fully exerted to reduce the cost of users.